Part 7: Detecting touches on the display, and improving on the original firmware

In the previous part, we were able to display images on the touch-screen. It's a natural next step to detect touches on the display.

screen1.jpg

To locate the code in the firmware disassembly that interface with the touch detection device, the easiest is to identify the pins connected with it. I've identified two pins connected to the display connector that are not used for driving the LCD display: PC7 and PC8. Therefore, they must be used for the sensing touches. Going through the various initialization routines, I found the touch detection initialization routines in the IDA Pro disassembly:

decompilation.png

The touch detection device seems vaguely similar to a FT5x16.

Essentially, there are 5 wires to interface it:

MCU Pin Name Description
PC7 CS Chip select wire. Must be driven low when communicating.
PC8 SCK SPI clock wire
PC9 MISO SPI master input / slave output
PA8 MOSI SPI master output / slave intput
PA9 TOUCH Driven high when there's a touch detected. Good to plug in on an interrupt line.

We can replicate the code to interface with the device, and detect touches. Note that we have to do the SPI interface in software as these pins are not connected to any hardware SPI peripherals.

The way the protocol goes is the following:

  • Send 0x90
  • Receive high 8 bit of the 16 bits value of x
  • Receive low 8 bit of the 16 bits value of x
  • Send 0xD0
  • Receive high 8 bit of the 16 bits value of y
  • Receive low 8 bit of the 16 bits value of y

Values needs to be scaled, debounced, but that's about it.

Here's a demo of the touch screen integrated with the display:

demo

Pretty cool!

Fixing the touch screen accuracy

The original firmware didn't handle finger touches so well, which is the reason why I always needed to use a stick on the touch screen.

See the problem:

bad1

At first, I'm pressing with my nail and the touch points are well detected. But then I use less pressing force and press with my finger pillow side. You can see the points are all over the place. This has bad consequences with the original firmware:

bad2

It doesn't detect the position of my finger correctly, and it goes all over the place. THe UI buttons are incorrectly pressed.

We can try probing for some pressure value. We know that 0x90 and 0xD0 are used to read x and y values, so perhaps the pressure value z isn't too far.

I tried reading values from commands 0x00 to 0xFF, and 0x16 seemed to be the only one related to the touch pressure. I found the touch pressure to be z = cmd(0x16)/y. It's a bit odd, but it works out. When z > 0.35, the touch points are reliable.

Here's how it looks when rejecting points with little pressure:

good

Much better! It's not the greatest touch screen in the world, but at least it's accurate.

Identifying the touch screen controller and improvements

Based on the protocol, Marijn correctly identified the touch screen controller as an XPT2046.

Few days later, I took a photo of the controller seen under the ribbon cable:

screen2.jpg

He got it right! Impressive!

Here's the datasheet of the XPT2046, which is essentially a clone of the ADS7846, originally made by the Burr-Brown corporation, acquired by Texas Instruments in 2000.

This provides visibility in what we were doing. The control bits are described:

tables.png

The command begins with a start bit S = 1, then three bits that constitute the actual command, then one bit to select 12 or 8-bit sampling, one bit to configure how the ADC is configured (0 is always good for us), and lastly two bits to configure power.

Regarding the 0x90 = 0b10010000 and 0xD0 = 0b11010000, clearly we see that it corresponds to the 001 and 101 commands from table II, measuring X and Y positions with 12-bit precision (mode = 0). (X and Y are swapped in our situation).

The command I used to detect pressure 0x16 = 0b00010110 doesn't exist, as it doesn't have a start bit. It worked because the first high bit signals the start of the command (unlike the SPI protocol, for which the chip select pin going down is the indication), and so the effective command I sent was 10110000. This measures the Z1 position in 12 bits precision.

pressure.png

Okay, so we were vaguely doing the (3) equation, but we missed the offset incurred by the X position (X and Y are swapped in our application).

We can improve the touchscreen accuracy with the following:

  • Leave the device powered on while sampling touch values, apparently that makes the VREF internal generator more stable, giving us better accuracy (which is what the differential reference mode uses)
  • Leave the CS pin down during the entire sampling of data
  • Do robust pressure measurements

Next, we are going to move the build plate.

Go to Part 8