Scale fields by a dimensionless number between 0 and 1 #4575

Merged
merged 6 commits into from
Jan 5, 2024

Conversation

RemiLehe
Copy link
Member

@RemiLehe RemiLehe commented Jan 4, 2024

It seems that, for rigidly injected particles, fields are being scaled by a time (in SI units, i.e. seconds), instead of a ratio of times (i.e. the ratio of the time spent to the right of the injecting plane, divided by the timestep).

This PR fixes this issue.

@RemiLehe RemiLehe requested a review from dpgrote January 4, 2024 21:23
@RemiLehe RemiLehe changed the title [WIP] Scale fields by a dimensionless number between 0 and 1 Scale fields by a dimensionless number between 0 and 1 Jan 4, 2024
Copy link
Member

@dpgrote dpgrote left a comment

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Thanks for catching and fixing this!

@RemiLehe RemiLehe enabled auto-merge (squash) January 4, 2024 21:42
@jlvay
Copy link
Member

jlvay commented Jan 4, 2024

Here is an input script that was used to identify the issue as well as a couple of plots that shows the effect.
inputs-ref.txt

  • Before the fix
    Before_fix
  • After the fix
    After_fix

@RemiLehe RemiLehe merged commit 685ae3f into ECP-WarpX:development Jan 5, 2024
41 checks passed